Many domestic refrigerators are equipped with an automatic ice makers. Automatic icemaker, mounted in the refrigerator. It is intended for manufacture of ice cubes automatically.

Typical ice is connected through the line and will harvest in the cooling or defrosting. Water valve and solenoid valve into the compressor compartment. In 3/16" (4.8 mm) polyethylene pipes are used for H20 (water) water flow valve to fill trough. Fig. 8-32 shows how the construction of a typical block.

Ice mold, figure S-33, thermostat, bonded to the front surface. The form has a semicircular bays. Water enters through the back and fills in each compartment. Mold heater is mounted on the underside of the ice mold. Cm. Fig. 8-34. Mold heater is connected in series with ice maker thermostat, which acts as a protective device. The heater is resting on top of the ice in the storage container. It will stop over ice in the course of the revolution. If the preset number of ice is removed, ice maker hand and reduces production resumes. When the container is full signal raises his hand, and the circuit is broken.

Icemaker, requires the proper functioning and synchronization of all components.

The following procedures must be defined when servicing ice. Make sure that;

  • Ice maker was properly installed and is connected to water and electricity.
  • Freezer is desired temperature. Check the temperature of the mold, to determine if it is above 15F (-9.5C)If the freeze temperatures above 15F, it is not cold enough to close the ice thermostat,
  • Several ice-making cycles were completed, and ice in the freezer cycle.
  • Icemaker, thermostat single-throw switch wired in series with the form of the heater.
  • Injector blades turn two times per one cycle, and that the ice is not stored on the blades after harvest.
  • Water solenoid valve is connected in series with the form of the heater.
The work of the ice maker can best be understood on the results of his work step by step. Fig. 8-35 are shown in the context of the appearance of the ice. Fig. 8-36 shows freeze cycle. Please note that all components are de-energized. Form, filled in with water.

The beginning of the harvest cycle is shown in Fig. 8-37. The thermostat is in the closed position, because the ice in the mold. Mold heater and working capital of the engine are energized. Injector blades begin to rotate. The motor turns a few degrees, figure 8-38, and timing Cam switches holding switch to its open position. This completes the cycle. Mold heater remains on the thermostat circuit. During the first half of the cycle, signal hand rises and falls on the terms of cam and acts on the circuit breaker. On Fig. 8-39, ejector blade contacts the ice in the mold and kiosks. Mold heater. Blade remains in this position until the ice melted lose.

On Fig. 8-40, the first revolution is nearly completed and deadlines cam closes the water solenoid valve and its transition. The thermostat is closed and mould heater operates. Current flows through the water solenoid valve and its transition. This is because the electric current is the path of least resistance...

 
Thanks ->



Cascade refrigeration system Chiller tube bundle repair Difference between fouling and scaling Effects of freezing on microorganisms Efficiency of compressor Flash intercooler Flooded evaporator Forced lubrication system wiki Heat of respiration Nomenclature of refrigerants Pressure enthalpy diagram ammonia Psc compressor Shell and tube condenser