Guidance on retrofitting to hfc 134a

Technical information Refrigerants Guidance on Retrofitting to R-134a

Guide for Retrofitting R-134a

Some systems have a device that will automatically release the refrigerant into the atmosphere to prevent the extremely high pressures. Any modernization of the system with such a device, using the new refrigerant high-pressure shut-off switch must be installed. This switch will prevent the compressor against pressure increase to the point where the refrigerant vented.

The term " modernization describes the special procedures required for the conversion of R-12 system to use an alternative refrigerant. This section describes some facts about the aftermarket functions and procedures for modernization Air conditioning and refrigeration systems for R-134a. As is known, R-134a is selected from around the world to be a long-term replacement of R-12 in refrigeration and air conditioning systems.

Producers (also known as original equipment manufacturers) have been developed upgrade kits or guidelines for some of the models.

These procedures were designed to provide the best level of performance with the new R-134a systems. While these kits and guidelines will provide the greatest assurance that a comparable system performance will be achieved, the cost of these procedures will in many cases be relatively high. Procedures necessary for the lowest cost of modernization are simple and do not require major changes in the components. As a rule, the process calls for the removal of the old refrigerant and installation of accessories and a new label, and the addition or polyalkylene glycol (PAG) or polyester (POE or ether) in the lubricant, as well as R-134a refrigerant.

According to the rules of the EPA, 2009), the use of any the alternative refrigerant for replacement of R-12 requires, as a minimum,

  • unique service fittings to be used in order to minimize the risk of cross-contamination, or the cooling system or service center recycling equipment;
  • new refrigerant be identified by a unique color for the identification of the refrigerant in the system;
  • all R-12 to be completely removed from the system before filling the system with the alternative refrigerant;
  • in order to prevent the release of refrigerant to the atmosphere of the high-pressure compressor shut-off switch be installed on any system equipped with a pressure-relief device;
  • separate equipment for recovery of R-12 from the system.
Also, alternative refrigerant blends containing R-22, should be used with barrier hoses...
 
Thanks ->



Absorbent refrigerant combination Bare tube evaporator Cooling and dehumidifying coils Electronic expansion valve wiki Evaporating temperature Evaporator construction Function of evaporator P. H. diagram Properties of ideal refrigerant Rotary compressor construction Rsir compressor Setting epr valve Shell and coil evaporator